PourGaugeHow much concrete you actually need, and what to mix into it.

How much does 1000 ft of #8 rebar weigh?

#8 rebar — 1000 ft
2,670lb
1″ diameter at 2.67 lb per foot — that is 50 lengths of 20 ft
#8 rebar — 1000 ft2,670 lbWeight of 1,000 ft0.79 in²Cross-section area
Diameter#8 means 8/8 of an inch1in
Weight per foot2.67lb/ft
Weight of 1,000 ft2,670lb
Lengths to buy (20 ft)yards also stock 10 and 40 ft in the common sizes50sticks
Cross-section areathe number that appears in an engineer’s drawing0.79in²
Typical lap splice40 × diameter — check the drawing, this is a common value not a rule40in

Notes

  • The number is the diameter in eighths of an inch. #8 rebar is 8/8 of an inch, which is 1″. That one rule covers every size from #3 to #11 and it is the fastest way to read a drawing without a chart. It stops working at #14 and #18, which are sized by area instead.
  • Weight is how rebar is priced and how it is handled. At 2.67 lb per foot, 1,000 ft comes to 2,670 lb — worth knowing before deciding whether this is a job for one person and a pickup.
  • Cross-section area (0.79 in²) is the number the engineer uses. When a drawing calls for a given area of steel per foot of wall, it is this figure being added up, not the diameter or the weight.
  • This page does not tell you what size to use. Bar size, spacing, cover and lap length come from the structural drawing and from local code. Slab-on-grade in a garage and a retaining wall holding back a hillside can both be "concrete with rebar in it" and share nothing else.
  • Figures are the ASTM A615 standard table, not one supplier's catalogue. Any yard selling to that standard sells the same bar to the same dimensions.

1000 ft of #8 rebar

2,670 lb, and that is 50 lengths of the 20 ft stock most yards sell.

Worth knowing before deciding whether this is a job for one person and a pickup.

The number is the diameter in eighths of an inch

#8 rebar is 8/8 of an inch — 1″.

That single rule reads every size from #3 to #11 without a chart, and it is the fastest thing to know on a site. It stops working at #14 and #18, which are sized by area instead.

The three numbers that matter

Diameter 1″
Weight 2.67 lb per foot
Cross-section 0.79 in²

Diameter is what you check on site. Weight is what you pay for and carry. Cross-section is the number the engineer uses — when a drawing calls for a given area of steel per foot of wall, this is the figure being added up.

Lap splices

About 40″ at 40 × diameter, which is a common value rather than a rule. The drawing and the local code decide it, and both can ask for more.

This page does not tell you what size to use

Bar size, spacing, cover and lap length come from the structural drawing and from local code. A garage slab and a retaining wall holding back a hillside are both "concrete with rebar in it" and share nothing else.

Figures here are the ASTM A615 standard table, not one supplier's catalogue — any yard selling to that standard sells the same bar.

Nearby sizes

Read more